Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
circuit-breaker

General Electrics TEY370ST12 - 70 A, 3-Pole Bolt-On Circuit Breaker | AmpState

Part Number TEY370ST12
Amperes 70
Poles 3
Product Type circuit-breaker
Icon
Manufacturer :General Electrics
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $710.00
Sale price $710.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
General Electrics TEY370ST12 - 70 A, 3-Pole Bolt-On Circuit Breaker | AmpState

General Electrics TEY370ST12 - 70 A, 3-Pole Bolt-On Circuit Breaker | AmpState

Regular price $710.00
Sale price $710.00 Regular price
Unit price
Product description
Shipping

Meet the General Electric TEY370ST12, a 70 A, 3-pole bolt-on molded case circuit breaker engineered for dependable branch circuit overcurrent and short-circuit protection in panelboards and loadcenters. Built to integrate seamlessly with matching OEM enclosures, this unit delivers reliable protection where it matters—home electrical panels, commercial distribution boards, and light industrial circuits.

  • Secure bolt-on mounting provides a rigid, vibration-resistant connection to the bus, maintaining consistent electrical performance even in environments with equipment movement or vibration.
  • Thermal-magnetic trip unit delivers stable, repeatable protection by quickly responding to both overloads and short circuits, reducing nuisance trips and protecting wiring and devices.
  • 3-pole configuration ensures synchronized protection across all phases, which is essential for balanced loads and safe operation of three-phase systems.
  • Molded case design combines compact form with durable insulation, simplifying installation in crowded panels and improving heat management under load.
  • OEM-compatible engineered to work with the corresponding General Electric loadcenters and panelboards, streamlining replacement and upgrade projects.

What problems does it solve? The TEY370ST12 guards electrical feeders against overcurrent conditions that can cause wiring damage, equipment failure, or fire risk. Its thermal-magnetic trip mechanism provides predictable and dependable interruption during sustained overloads and sudden short circuits, helping keep critical circuits protected without unnecessary disruption.

Ideal for: electricians, facilities managers, and electrical contractors working on residential, commercial, and light industrial projects. Whether upgrading an aging panel, replacing a failed breaker, or stocking spare parts for service calls, this unit fits standard General Electric panelboards and loadcenters that require a 70 A, 3-pole bolt-on breaker.

Use cases and practical guidance

  • Upgrading service panels in multifamily housing where dependable phase protection and secure mounting reduce maintenance calls.
  • Mid-scale commercial installations with three-phase equipment, where synchronized trip across all poles is essential for safety and equipment protection.
  • Electrical retrofit projects in light industrial facilities that demand a rugged bolt-on solution capable of withstanding vibration and heat buildup.

Compared to non-bolt-on or less robust trip designs, the TEY370ST12 prioritizes long-term reliability and ease of servicing. Its bolt-on style creates a solid electrical connection that resists loosening over time, while the thermal-magnetic mechanism minimizes unwanted trips and maintains protective performance as ambient conditions change.

Technical at a glance: General Electric TEY370ST12, 70 A, 3 poles, bolt-on mounting, molded case circuit breaker for branch circuit overcurrent and short-circuit protection. This unit is purpose-built to deliver dependable protection in residential, commercial, and light industrial panelboards and loadcenters.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Consistent quality. We’ve added similar items to our regular reorder list.

MRO · Reorder

Verified

Support is responsive when we have questions about fit or application.

Purchasing · Quick answers

Verified

A reliable choice when we need industrial parts on short notice.

Service · Urgent replacement

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day