Circuit Breaker

THJK 2-Pole Molded Case Circuit Breaker, 600V, 600A Frame, Custom Trip Unit, 30kAIC @ 480V / 22kAIC @ 600V

Amperes 600
Poles 2
Voltage 600
Product Type Circuit Breaker
Icon
Manufacturer :General Electric
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $3,850.00
Sale price $3,850.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
Allen-Bradley LOGIX5000 - In Box! .A Battery Assembly 1756-Ba1 - In Box! .A Battery Assembly 1756-Ba1

THJK 2-Pole Molded Case Circuit Breaker, 600V, 600A Frame, Custom Trip Unit, 30kAIC @ 480V / 22kAIC @ 600V

Regular price $3,850.00
Sale price $3,850.00 Regular price
Unit price
Product description
Shipping

Engineered for demanding 600-volt electrical environments, the THJK 2-Pole Molded Case Circuit Breaker delivers tailored protection exactly where you need it. Built on a robust THJK frame with a 600A rating and a 600V-rated trip unit, this conjunction of hardware and software-like protection curves is designed to meet project-specific requirements without compromise.

The standout strength of this breaker is its Custom Trip Unit. Instead of a one-size-fits-all setting, the trip unit is configured to match your unique loading profiles, coordination with upstream protection, and specific startup/stop characteristics. This means faster fault clearances where you want them and selective tripping where you don’t, reducing nuisance trips and protecting sensitive equipment along the power path.

Quality you can trust begins before the first current is carried. Each THJK 2-pole assembly is custom-built from the proven THJK frame and undergoes rigorous secondary injection testing. This testing validates trip performance and protection settings in a controlled, repeatable way, ensuring the unit behaves exactly as designed when it encounters real fault conditions.

Key specifications at a glance

  • Frame Type: THJK
  • Poles: 2
  • Frame Rating: 600 A
  • Voltage Rating: 600 V
  • Interrupting Capacity: 30 kAIC @ 480 V / 22 kAIC @ 600 V
  • Construction: Custom-built from THJK frame with a 600 V trip unit
  • Testing: Secondary injection testing performed prior to delivery

Who should consider this breaker? facilities with 600V distributions, industrial plants with large motor drives, data centers and critical load feeders, or panel assemblies requiring precise protection coordination. The 2-pole design is ideal for protecting paired circuits or feeder breaks, while the 600 A frame supports substantial continuous currents without compromising protection accuracy.

Why choose this solution over generic breakers? It’s the combination of a purpose-built trip unit and verifiable testing. You get customized protection curves that align with your system’s dynamic loads, plus documented verification that the unit will trip correctly under fault conditions. The result is improved reliability, reduced downtime risk, and easier compliance with internal protection coordination standards.

Practical use cases include protecting 600V feeders feeding motors, HVAC systems, processing lines, and critical machinery where coordinated protection minimizes both equipment exposure and arc-flash risk. If you’re upgrading an MCC, panelboard, or main distribution scheme, this THJK 2-pole breaker provides a precisely tuned, thoroughly tested solution that can be integrated into existing protection schemes with confidence.

Installation considerations: plan conductor sizing and bus connections for 600V operation, and align the custom trip settings with your protection philosophy (e.g., definite-time vs. inverse-time characteristics, if applicable). Because the unit is tested before delivery, you’ll spend less time on commissioning and more time maintaining uptime in your operations.

For engineers and procurement teams seeking a dependable, project-ready protection device for 600V systems, the THJK 2-Pole Molded Case Circuit Breaker combines a strong mechanical platform with a configurable protection strategy—and it’s backed by thorough secondary injection testing to verify proper operation before it leaves the shop.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Feels well-built and suitable for everyday plant and maintenance use.

Facilities · Manufacturing

Verified

Lead time was reasonable and the part matched expectations when it arrived.

Procurement · Ontario

Verified

Good value for industrial use. Customers mention easy installation.

Service tech · Field work

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day