Breaker MCC Bucket

GE 7700 - Cutler Hammer 9800 Unitrol - Breaker MCC Bucket - 60 A, 600 V, 18" Height, 3 P | AmpState

Series GE 7700
Amperes 60
Poles 3
Voltage 600
Product Type Breaker MCC Bucket
Icon
Manufacturer :GE
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $4,210.00
Sale price $4,210.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
GE 7700 - Cutler Hammer 9800 Unitrol - Breaker MCC Bucket - 60 A, 600 V, 18" Height, 3 P | AmpState

GE 7700 - Cutler Hammer 9800 Unitrol - Breaker MCC Bucket - 60 A, 600 V, 18" Height, 3 P | AmpState

Regular price $4,210.00
Sale price $4,210.00 Regular price
Unit price
Product description
Shipping

The GE 7700 Breaker MCC Bucket from the 9800 Unitrol family is built to protect and control demanding industrial motors with precision. Engineered as a direct replacement or retrofit for GE 7700 motor control centers, this 60 A, 600 V, 3-Pole MCC bucket delivers reliable protection and streamlined maintenance in harsh plant environments.

  • Exact fit for GE 7700 MCCs – Designed to drop into existing GE 7700 frames with minimal modification, reducing downtime during upgrades or repairs.
  • 60 A, 600 V, 3-Pole configuration – Three-phase protection and switching for balanced motor loads, aligning with common industrial drive specs and wiring schemes.
  • 18" bucket height – Standardized geometry that matches typical GE rack layouts, ensuring clean serviceability and consistent spacing within the MCC.
  • Direct replacement or retrofit – Simplifies modernization or spare-part strategy, allowing maintenance teams to refresh aging centers without a full rebuild.
  • Part of the Cutler-Hammer 9800 Unitrol lineage – Built on a legacy of robust performance, known for dependable control and protection in demanding operations.

Who benefits most?

  • Facilities running legacy GE 7700 motor control centers that need reliable, compatible MCC buckets without expensive reconfiguration.
  • Maintenance teams seeking a ready-to-install solution for spare-part readiness or scheduled retrofits in manufacturing, processing, and packaging lines.
  • Industries with heavy-duty motors and frequent start–stop cycles where dependable protection and quick replacements matter most.

Practical value and use cases:

  • Retrofit projects to extend the life of aging MCCs while preserving existing wiring and bus configurations.
  • New installations that require a proven 3-Pole, 60 A breaker bucket compatible with GE 9800 Unitrol systems.
  • Maintenance planning with standardized 18" buckets to simplify stocking and service workflows.

Why choose AmpState for this MCC bucket?

  • Global delivery and reliable logistics to keep your project on schedule, wherever you are.
  • Technical support from specialists who understand industrial motor control and retrofit nuances.
  • Quality assurances and access to genuine replacement pieces within the 9800 Unitrol family, ensuring compatibility and performance.

Compatibility and installation notes (quick checklist):

  • Confirm the target MCC is GE 7700 and that the application requires a 60 A, 600 V, 3-Pole configuration.
  • Verify bucket height is 18" to match your existing rack footprint and mounting points.
  • Ensure electrical and mechanical alignment with the bus bars and mounting hardware in your MCC cavity.
  • Engage a licensed electrician or qualified technician for installation and safety compliance.

For facilities upgrading or maintaining industrial motor control, the GE 7700 Breaker MCC Bucket (60 A, 600 V, 3-Pole) offers a precise, dependable solution that aligns with GE’s Unitrol architecture and your plant’s operational demands. Trust AmpState for compatible replacements, seamless retrofits, and expert support to keep your motor control center running smoothly.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Feels well-built and suitable for everyday plant and maintenance use.

Facilities · Manufacturing

Verified

Lead time was reasonable and the part matched expectations when it arrived.

Procurement · Ontario

Verified

Good value for industrial use. Customers mention easy installation.

Service tech · Field work

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day