Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
circuit-breaker

Eaton PDG23P0040TFFJ - 40 A, 600 V, 3-Pole Circuit Breaker | AmpState

Part Number PDG23P0040TFFJ
Amperes 40
Poles 3
Voltage 600
Product Type circuit-breaker
Icon
Manufacturer :Eaton
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $710.00
Sale price $710.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
Eaton PDG23P0040TFFJ - 40 A, 600 V, 3-Pole Circuit Breaker | AmpState

Eaton PDG23P0040TFFJ - 40 A, 600 V, 3-Pole Circuit Breaker | AmpState

Regular price $710.00
Sale price $710.00 Regular price
Unit price
Product description
Shipping
Eaton PDG23P0040TFFJ is a 40A, 600V, 3-pole molded case circuit breaker purpose-built to protect critical electrical circuits in panelboards and load centers. Its compact design maximizes panel space while delivering precise, reliable protection for a wide range of installations—from homes to light commercial and industrial environments. Key features that matter in real-world panels - Amperage and voltage: 40A at up to 600V, three-pole configuration for three hot conductors in 3‑phase or multi‑wire systems. - Thermal-magnetic trip unit: combines a thermal element for stable, predictable response with a magnetic element for rapid short-circuit clearing, reducing the risk of damage and downtime. - Space-efficient molded case: streamlined footprint that helps you fit essential protection where panel space is at a premium. - OEM panel compatibility: designed to integrate with matching OEM load centers and panelboards for reliable fit and coordinated protection. - Versatility across applications: suitable for residential, commercial, and light industrial circuits that require robust branch-circuit overcurrent and short-circuit protection. Why this 3-pole breaker makes sense - Three-pole protection in a single unit simplifies wiring and enhances protection coordination for 3‑phase equipment, motors, and HVAC feeds, while maintaining a clean, organized panel interior. - The molded case construction provides durable, long-term performance in standard electrical environments, helping to minimize nuisance trips and maintain service continuity. - OEM-compatible design means easier replacements and maintenance, with consistent performance across compatible panelboards and load centers. Ideal use scenarios - Protecting three‑phase feeders or motor circuits in commercial spaces, small manufacturing, or service areas where 600V systems are in play. - Upgrading or replacing aging protection in panelboards that require a reliable 3-pole, 40A solution with a clear trip mechanism. - Retrofitting new protection into existing OEM panels without sacrificing fit or electrical coordination. What sets it apart from generic breakers - The combination of a 40A rating, 600V capability, and a true thermal-magnetic trip in a compact molded-case package delivers precise, repeatable protection for demanding environments. - OEM compatibility reduces installation complexity and ensures consistent behavior across the panel system, avoiding mismatches that can lead to improper protection. - The three-pole design consolidates circuit protection for multi-conductor loads, supporting cleaner wiring layouts and easier serviceability. Practical tips for installation and use - Install only in panels and load centers that specify compatibility with this PDG series device and 3-pole molded-case breakers. - Verify that the circuit load does not exceed the 40A rating and that the connected equipment is suitable for up to 600V operation. - When replacing an existing breaker, ensure the new unit aligns with the same bus type and mounting arrangement to maintain proper electrical contact and protection performance. - Schedule regular inspections of panel interiors, checking for signs of wear, heat discoloration, or loose terminals, and reseat connections with appropriate torque as per panel guidelines. Specs at a glance - Manufacturer: Eaton - Part Number: PDG23P0040TFFJ - Type: Thermal-magnetic molded case circuit breaker - Amperage: 40A - Voltage: 600V - Poles: 3 - Application: Branch circuit overcurrent and short-circuit protection in panelboards and load centers The Eaton PDG23P0040TFFJ delivers dependable, three‑pole protection for demanding electrical layouts, marrying compact design with a responsive thermal-magnetic trip that keeps systems running smoothly. For professionals who demand precise protection in commercial, residential, and light industrial settings, this is a reliable, easy-to-integrate choice.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Professional-grade feel. No issues reported during commissioning.

Controls · Commissioning

Verified

Arrived in good condition and helped keep our project on schedule.

Project team · Contractor

Verified

Exactly what most contractors expect from an industrial supplier.

Electrical · Commercial

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day