Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
Circuit Breaker

Eaton | CND3800T36W | Circuit Breaker | 800A | 3-Pole | 600V | 50kA | Bolt-On

Part Number CND3800T36W
Amperes 800
Poles 3
Voltage 600
Product Type Circuit Breaker
Icon
Manufacturer :Eaton
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $19,760.00
Sale price $19,760.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
Allen-Bradley 140M-C2E-C16 - Standard Magnetic Trip Breaker Motor Protection - Standard Magnetic Trip Breaker Motor Protection

Eaton | CND3800T36W | Circuit Breaker | 800A | 3-Pole | 600V | 50kA | Bolt-On

Regular price $19,760.00
Sale price $19,760.00 Regular price
Unit price
Product description
Shipping
Eaton CND3800T36W is a purpose-built bolt-on circuit breaker designed to protect large, 3-phase circuits with precision and enduring reliability. With an 800A rating, three poles, and a robust 50kA interrupting capacity at 600V, this breaker is engineered for demanding industrial environments where downtime is not an option and safety is paramount. Whether you’re retrofitting aging gear, upgrading a panel, or replacing a worn breaker, this model delivers a seamless fit and dependable protection. Key specifications - Amperage: 800A - Poles: 3-Pole - Voltage: 600V - Interrupting rating: 50kA - Mounting: Bolt-On - Part reference: CND3800T36W Why this breaker matters for your system - High-load protection: The 800A rating supports large motors, feeders, and three-phase distribution networks common in manufacturing floors and commercial facilities. - Reliable three-phase protection: A true 3-pole design ensures synchronized tripping across all phases, reducing the risk of unbalanced faults and equipment damage. - Robust mounting: Bolt-On construction provides secure, vibration-resistant installation in compatible panels, helping to minimize loosening and maintenance over time. - Durable performance at 600V: Built to handle the voltage levels typical of industrial equipment, ensuring consistent protection across your critical circuits. - Strong fault handling: With a 50kA interrupting capacity, this breaker is designed to rapidly interrupt faults, helping to limit damage and downtime in your power system. Ideal use cases and scenarios - Retrofit projects in existing Eaton or compatible panelboards where an 800A, 3-pole, 600V bolt-on breaker is required. - Replacement for aging or failed circuit breakers in heavy-load distribution circuits that service motors, conveyors, or large HVAC equipment. - Maintenance outages or upgrade cycles where a dependable, high-capacity breaker is needed to minimize disruption. - New installations in facilities with demanding three-phase loads, where a bolt-on mounting solution ensures a secure, durable fit. What sets it apart (and why you should choose it) - Purpose-built for retrofit and replacement workflows: The CND3800T36W aligns with established Eaton specifications, making compatibility straightforward when upgrading or maintaining your electrical infrastructure. - Clear compatibility reference: The part number is the best guide for matching against your panel and existing components—verify fit and ratings before ordering to ensure a flawless upgrade. - Real-world reliability: Designed to withstand the rigors of industrial environments, this breaker supports long-term service in critical power paths without frequent replacements. Practical guidance for installation and care - Before ordering, confirm that your panel accepts bolt-on breakers and that the electrical ratings match your system requirements. - Follow your panel manufacturer’s torque and mounting guidelines to ensure secure, dependable operation. - Clearly label the circuit and keep a spare compatible breaker on site to reduce downtime during maintenance windows. - Use in conjunction with proper enclosure ventilation and routine electrical inspection practices to maintain peak performance. If your project demands robust three-phase protection with a secure bolt-on mount, the Eaton CND3800T36W delivers the capacity, reliability, and compatibility you need. Add it to your order to ensure your heavy-load circuits stay protected, compliant, and ready for operation.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Matched our existing hardware and fit as expected. Clean install.

Maintenance · Retrofit work

Verified

Quick confirmation on details and a smooth ordering process.

Purchasing · Fast turnaround

Verified

Came well packed. Labeling made receiving and staging easy.

Warehouse · Receiving

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day