Eaton BAB3060HS - 60 A, 240 V, 3-Pole Bolt-On Circuit Breaker | AmpState

Part Number BAB3060HS
Amperes 60
Poles 3
Voltage 240
Product Type circuit-breaker
Icon
Manufacturer :Eaton
Icon
Replacement available
Icon
Picture available on request
Icon
CSA / UL Approved
Regular price $710.00
Sale price $710.00 Regular price
Unit price
Save

Seamless online shopping experience guaranteed with easy shipping and returns policy.

Shop with Confidence: Our Products come with a Reliable Year-Long Warranty.

Icon
Secure transaction
Icon
FREE & fast shipping on orders over $49
Icon
CSA approved with 1 year warranty
Icon
30 day returns
Eaton BAB3060HS - 60 A, 240 V, 3-Pole Bolt-On Circuit Breaker | AmpState

Eaton BAB3060HS - 60 A, 240 V, 3-Pole Bolt-On Circuit Breaker | AmpState

Regular price $710.00
Sale price $710.00 Regular price
Unit price
Product description
Shipping

The Eaton BAB3060HS stands as a dependable, ready-to-install solution for protecting branch circuits in panelboards and load centers. Delivering 60A at 240V with a rugged three-pole bolt-on design, this molded case circuit breaker is built to handle the demands of residential, commercial, and light industrial environments.

Key advantages that set the BAB3060HS apart

  • Secure bolt-on mounting for a rigid, vibration-resistant bus connection. This design minimizes loose connections and maintains consistent electrical contact in facilities where equipment experiences movement or vibration.
  • Thermal-magnetic trip unit delivers stable, repeatable protection. The thermal element handles overloads predictably while the magnetic element provides fast, decisive response to short circuits, helping to minimize damage and downtime.
  • Three-pole protection ensures balanced, coordinated shutdown across all phases in three-phase systems, reducing the risk of unmanaged fault currents and improving overall system safety.
  • OEM-compatible specifically engineered to integrate with matching Eaton panelboards and load centers, ensuring proper fit, electrical coordination, and ease of replacement without additional adaptors.
  • Versatile application ideal for residential, commercial, and light industrial applications requiring reliable branch circuit overcurrent and short-circuit protection.

Why this breaker matters for your panels

If you’re upgrading or stocking spare parts for Eaton-compatible installations, the BAB3060HS provides a precise match for currently installed equipment. Its bolt-on design simplifies field replacement in panelboards and load centers, helping you maintain quick restoration of service with a secure, code-compliant connection. The 60A rating is well-suited for mid-size branch circuits, feeders, and equipment loads that demand robust protection.

Practical use cases

  • Mid-size commercial distribution panels where reliable three-phase protection keeps HVAC, lighting, and outlets safe from faults.
  • Residential service panels with multi-wire branch circuits requiring clear overcurrent protection and straightforward maintenance.
  • Light industrial panels powering small motors or conveyors where vibration resistance and dependable trip performance are critical.

What you gain with the BAB3060HS

  • backed by a thermal-magnetic mechanism that reduces nuisance trips while preserving fast fault clearance.
  • thanks to a sturdy bolt-on mount that maintains a solid connection through years of service and minor disturbances.
  • with Eaton’s family of panelboards and load centers, streamlining installation, maintenance, and future replacements.

Technical snapshot

Manufacturer: Eaton
Part number: BAB3060HS
Type: Thermal-magnetic molded case circuit breaker
Amperage rating: 60A
Voltage rating: 240V
Number of poles: 3
Mounting style: Bolt-on
Application: Branch circuit overcurrent and short-circuit protection

Practical installation tips

Ensure the panelboard is de-energized before installation, torque mounting screws to the manufacturer’s specification, and verify that the breaker aligns properly with the bus bars. Confirm that the Eaton BAB3060HS is the correct matching unit for your specific load center or panelboard model to maintain proper electrical coordination and labeling.

Contact sales@ampstate.com

Shipping cost is based on weight. Just add products to your cart and use the Shipping Calculator to see the shipping price.

We want you to be 100% satisfied with your purchase.

What Our Customers Say

4.9 (38 reviews)

General feedback we often hear from customers purchasing industrial electrical parts.

Verified

Consistent quality. We’ve added similar items to our regular reorder list.

MRO · Reorder

Verified

Support is responsive when we have questions about fit or application.

Purchasing · Quick answers

Verified

A reliable choice when we need industrial parts on short notice.

Service · Urgent replacement

Fast industrial sourcing support

Need help?

  • Request a quote
  • Need a BOM priced for your project
  • Not sure which part is correct
  • Need an equivalent or replacement
  • Send your part list and get a fast reply

Email us at sales@ampstate.com for pricing, availability, alternates, and project support.

Email for a quote Typical reply: same business day