{"product_id":"square-d-vhu362rb-disconnect-switch-2","title":"Square D VHU362RB - 60A, 3-Pole, Non-Fusible Disconnect Switch","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the Square D VHU362RB—a rugged 60A, 3-Pole non-fusible disconnect switch designed for industrial and commercial environments where safe, reliable electrical isolation is non-negotiable. This unit delivers dependable disconnection under load, supports robust lockout\/tagout procedures, and stands up to long-term service in demanding setups.\u003c\/p\u003e \u003ch2\u003eKey specifications that matter in real-world applications\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eAmperage rating:\u003c\/strong\u003e 60A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole for full three-phase isolation\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure rating:\u003c\/strong\u003e NEMA 3R, suitable for outdoor and indoor installations\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Non-Fusible Disconnect Switch\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Square D VHU362RB\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eWhy this non-fusible switch matters in the field\u003c\/h2\u003e\n\u003cp\u003eIn many facilities, quick, safe isolation of power is essential for maintenance, repair, and safety compliance. The VHU362RB is built to cleanly interrupt power without the complexity of fuse handling, reducing downtime and simplifying routine work. Its three-pole design ensures that all conductors in a three-phase system are simultaneously isolated, minimizing residual energy and the risk of cross-phase faults during servicing.\u003c\/p\u003e \u003ch2\u003eUnique benefits you’ll notice on site\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eEnhanced safety with lockout\/tagout readiness:\u003c\/strong\u003e The disconnect switch pairs with standard lockout devices so technicians can lock out circuits during service, delivering peace of mind and compliance with safety protocols.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eReliable disconnection under load:\u003c\/strong\u003e Engineered to interrupt live circuits safely, helping prevent unexpected energization while equipment is being serviced.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDurable, weather-conscious enclosure (NEMA 3R):\u003c\/strong\u003e Protects the switching mechanism from the elements, making it a dependable choice for outdoor applications and variable work environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMaintenance-friendly and cost-efficient:\u003c\/strong\u003e As a non-fusible design, there are no fuses to stock or replace, reducing ongoing maintenance tasks and inventory needs.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStraightforward three-phase isolation:\u003c\/strong\u003e The 3-pole configuration ensures consistent, simultaneous disengagement across all phases, simplifying wiring and improving safety margins.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eIdeal use scenarios\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eIndustrial machinery and production lines that require a quick, clean power cut for maintenance.\u003c\/li\u003e \u003cli\u003eCommercial electrical rooms and service entrances needing reliable isolation with weather-ready protection.\u003c\/li\u003e \u003cli\u003eOutdoor equipment enclosures, pump stations, and HVAC systems where robust enclosure protection is essential.\u003c\/li\u003e \u003cli\u003eElectrical rooms and control panels where lockout\/tagout compliance is part of daily safety routines.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eChoosing between non-fusible and fused options\u003c\/h2\u003e\n\u003cp\u003eThe Square D VHU362RB provides instantaneous isolation without the need for fuse management, which can reduce downtime and simplify maintenance workflows. For environments where fuse replacement is impractical or costly, a non-fusible disconnect like this model offers a pragmatic, durable solution that keeps operations moving smoothly while maintaining rigorous safety standards.\u003c\/p\u003e \u003ch2\u003ePractical tips for installation and upkeep\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eVerify the environment aligns with the NEMA 3R enclosure rating to ensure optimal performance and longevity.\u003c\/li\u003e \u003cli\u003ePair the disconnect with standard lockout devices to support compliant, safe maintenance practices.\u003c\/li\u003e \u003cli\u003eSchedule periodic inspections to confirm the enclosure and switching mechanism remain free of corrosion, debris, and moisture ingress.\u003c\/li\u003e \u003cli\u003eKeep detailed wiring diagrams on hand and label conductors clearly to streamline future servicing and fault isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Amp-State","offers":[{"title":"Default Title","offer_id":46383502688418,"sku":"VHU362RB","price":1110.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/square-d-vhu362rb-60a-3-pole-non-fusible-disconnect-switch-652.webp?v=1788800650","url":"https:\/\/www.ampstate.com\/products\/square-d-vhu362rb-disconnect-switch-2","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}