{"product_id":"square-d-qdp32200tm-200a-240v-3-pole-bolt-on-circuit-breaker","title":"Square D QDP32200TM - 200 A, 240 V, 3-Pole Bolt-On Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the \u003cstrong\u003eSquare D QDP32200TM\u003c\/strong\u003e—the bolt-on, molded case circuit breaker designed to safeguard your most critical electrical loads. Rated for \u003cstrong\u003e200 A\u003c\/strong\u003e at \u003cstrong\u003e240 V\u003c\/strong\u003e and built as a \u003cstrong\u003e3-pole\u003c\/strong\u003e device, it delivers reliable protection for branch circuits in panelboards and load centers.\u003c\/p\u003e \u003cp\u003eKey features that set this breaker apart:\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSecure bolt-on mounting\u003c\/strong\u003e provides a rigid, vibration-resistant bus connection for dependable long-term performance.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e delivers stable, repeatable protection—thermal protection for overloads and magnetic trip for short circuits, helping you minimize nuisance trips while guarding life-safety loads.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-compatible design\u003c\/strong\u003e ensures seamless integration with matching Square D load centers and panelboards, making replacements and upgrades straightforward.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile application\u003c\/strong\u003e suitable for \u003cem\u003eresidential, commercial, and light industrial\u003c\/em\u003e environments, where robust protection and reliable operation are critical.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHigh-current capability\u003c\/strong\u003e 200 A at 240 V, 3-pole configuration, ideal for protecting substantial branch circuits without compromising system safety.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy choose bolt-on over other breaker styles?\u003c\/h3\u003e\n\u003cp\u003eUnlike plug-in options, bolt-on mounting secures the breaker directly to the panel’s bus, reducing movement and wear in busy electrical environments. This translates to fewer maintenance concerns and a more dependable protection scheme in panels that experience vibration or frequent switching.\u003c\/p\u003e \u003ch3\u003ePractical use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eMain protection for mid-size commercial panels and load centers requiring a 3-pole, 200 A solution.\u003c\/li\u003e \u003cli\u003eReplacement or upgrade in existing installations where OEM compatibility with Square D panels is essential.\u003c\/li\u003e \u003cli\u003eApplications where consistent thermal-magnetic protection helps prevent nuisance trips while delivering fast response to short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical snapshot\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Square D\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e QDP32200TM\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Thermal-magnetic molded case circuit breaker\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 200 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 240 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Bolt-on\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Branch circuit overcurrent and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eHow this fits into your electrical system\u003c\/h3\u003e\n\u003cp\u003eThis breaker is a purpose-built solution for panelboards and load centers that demand consistent performance under demanding conditions. It aligns with your existing Square D ecosystem, helping you maintain system universality, simplify stocking, and ensure compatibility with other protection devices within the same lineup.\u003c\/p\u003e \u003ch3\u003eMaintenance and best practices\u003c\/h3\u003e\n\u003cp\u003eFor enduring reliability, follow standard installation torque specifications and ensure the bolt-on mounting remains tight after initial commissioning. Schedule routine inspections of the trip function and verify the panelboard is in an environment within the breaker’s rated operating range. When in doubt, refer to your panelboard’s documentation and adhere to local electrical codes.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46355383517346,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/schnieder_and_square_d_breaker_and_panel_1bb6643c-7031-4c4b-b802-2105fc0e230e.png?v=1764691684","url":"https:\/\/www.ampstate.com\/products\/square-d-qdp32200tm-200a-240v-3-pole-bolt-on-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}