{"product_id":"siemens-tiastar-95-breaker-mcc-bucket-100-a-600-v-36-height-3-p-ampstate","title":"Siemens TIASTAR 95+ - Breaker MCC Bucket - 100 A, 600 V, 36\" Height, 3 P | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eThe Siemens TIASTAR 95+ Breaker MCC Bucket from AmpState is purpose-built for industrial motor control centers that require a precise 100 A, 600 V, 3-pole configuration. Designed as a direct replacement for Siemens TIASTAR 95+ MCC systems, this 36\" tall bucket ensures seamless retrofits and OEM compatibility, helping you keep downtime to a minimum while preserving the integrity of your motor control architecture.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Siemens TIASTAR 95+ Breaker MCC Bucket\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Breaker MCC Bucket for 3-pole protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 100 A, 600 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 36 inches\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Fits Siemens TIASTAR 95+ MCC systems; ideal for OEM replacements and retrofits\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy this MCC bucket is a smart choice\u003c\/h3\u003e\n\u003cp\u003eIn any medium- to large-scale electrical room, reliability and compatibility matter as much as performance. The TIASTAR 95+ Breaker MCC Bucket is engineered to slot into existing Siemens TIASTAR 95+ installations without the guesswork of mismatched bus bars or mounting points. Its 3-pole design provides balanced three-phase protection, ensuring synchronized motor startup and stable operation for pumps, conveyors, fans, and other heavy loads typical of industrial facilities.\u003c\/p\u003e \u003ch3\u003eWho benefits most\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eManufacturing facilities upgrading aging motor control centers\u003c\/li\u003e \u003cli\u003eOEMs integrating Siemens TIASTAR 95+ into new builds or retrofits\u003c\/li\u003e \u003cli\u003eElectrical maintenance teams seeking reliable, field-ready replacement parts with proven performance\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhat makes it different from generic replacements\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDirect compatibility:\u003c\/strong\u003e Specifically designed as a drop-in replacement for Siemens TIASTAR 95+ MCC systems, reducing installation risk.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eExact form factor:\u003c\/strong\u003e 36\" height aligns with standard MCC cabinets, preserving spacing, clearances, and bus alignment.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e3-pole protection at 100 A\/600 V:\u003c\/strong\u003e Tailored for common industrial loads while maintaining robust fault protection and clear coordination with upstream protection devices.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-grade reliability:\u003c\/strong\u003e Sonic match to original Siemens components, supporting predictable electrical performance and service life.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGlobal availability:\u003c\/strong\u003e AmpState backs with reliable sourcing and worldwide shipping, so replacements reach you quickly, wherever you are.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003ePractical use cases and scenarios\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eRetrofits in older Siemens MCCs to extend service life without redesigning the control scheme.\u003c\/li\u003e \u003cli\u003eNew installations within processes that demand consistent 3-phase protection and modular maintenance access.\u003c\/li\u003e \u003cli\u003eSpare-part strategy for critical motors—reducing downtime by keeping authentic replacement buckets in stock.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eInstallation and operational tips\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eVerify that your existing MCC cabinet and bus bar geometry match the TIASTAR 95+ bucket’s specifications before replacement.\u003c\/li\u003e \u003cli\u003eEnsure proper safety protocols and lockout\/tagout procedures during removal and installation.\u003c\/li\u003e \u003cli\u003eCoordinate with your electrical protection scheme to confirm compatible trip ratings and coordination with upstream devices.\u003c\/li\u003e \u003cli\u003eKeep an on-hand spare bucket to minimize downtime during scheduled maintenance or unexpected faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"AmpState","offers":[{"title":"Default Title","offer_id":46328515330210,"sku":null,"price":4210.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/siemens_model_90_95_95_marq_21_19e18e01-e1fd-40e9-926c-50bfbb6ba35b.jpg?v=1763623819","url":"https:\/\/www.ampstate.com\/products\/siemens-tiastar-95-breaker-mcc-bucket-100-a-600-v-36-height-3-p-ampstate","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}