{"product_id":"schneider-electric-nw25h2-2500a-3-pole-air-circuit-breaker","title":"Schneider Electric NW25H2 2500A 3-Pole Air Circuit Breaker For Low-Voltage Power Distribution","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the Schneider Electric NW25H2, a 2500 A, 3-Pole Air Circuit Breaker purpose-built for reliable protection and swift switching in low-voltage power distribution systems. Engineered for industrial and commercial facilities, this heavy-duty device protects main incoming feeders and switchboards, helping you maintain uptime and safeguard critical loads with coordinated, adjustable trip settings.\u003c\/p\u003e \u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe NW25H2 combines robust construction with precise protection logic to manage fault currents in busy electrical environments. As a 3-Pole air circuit breaker, it provides dependable, rapid isolation of faults while supporting tailored protection curves through adjustable trip settings. Designed to integrate seamlessly into existing low-voltage distribution architectures, it helps you balance safety, selectivity, and reliability across your facility.\u003c\/p\u003e \u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eCurrent rating: 2500 A\u003c\/li\u003e \u003cli\u003eConfiguration: 3-Pole air circuit breaker\u003c\/li\u003e \u003cli\u003eTrip architecture: Adjustable trip settings for protection coordination\u003c\/li\u003e \u003cli\u003eApplication: Ideal for main incoming feeders and switchboards in industrial and commercial environments\u003c\/li\u003e \u003cli\u003eProtection approach: Robust arc-quenching and switching performance designed for high-demand low-voltage power distribution\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eWhy it matters\u003c\/h2\u003e\n\u003cp\u003eIn any facility with significant electrical load, fast and selective fault isolation is critical. The NW25H2 delivers high interruption capability tailored to your protection scheme, reducing the risk of widespread outages and protecting both equipment and personnel. Its adjustable trip settings let you align device response with upstream protection and specific load characteristics, ensuring you isolate only the affected circuit while keeping everything else online.\u003c\/p\u003e \u003ch2\u003eIdeal use cases\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eMain incoming feeders for large switchboards and distribution panels\u003c\/li\u003e \u003cli\u003eProtection and switching in industrial facilities with heavy electrical demand\u003c\/li\u003e \u003cli\u003eCritical power distribution networks where coordination with upstream protective devices is essential\u003c\/li\u003e \u003cli\u003eCommercial installations requiring reliable low-voltage distribution protection with adjustable trip curves\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003ePerformance and reliability\u003c\/h2\u003e\n\u003cp\u003eBuilt to endure the rigors of busy facilities, the NW25H2 combines durable materials with a proven air-break mechanism. This design supports consistent performance under fluctuating loads and fault conditions, helping minimize downtime and extend the life of downstream equipment. Its 3-Pole configuration ensures balanced protection across phases, improving system stability during faults.\u003c\/p\u003e \u003ch2\u003ePractical deployment tips\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eConfirm compatibility with your panel layout, mounting provisions, and busbar configuration to optimize space and accessibility.\u003c\/li\u003e \u003cli\u003eCoordinate the adjustable trip settings with upstream protection devices to achieve selective tripping and minimize unnecessary outages.\u003c\/li\u003e \u003cli\u003eRefer to the facility’s protection scheme to set the correct trip thresholds for each load segment, ensuring fast isolation of faults without perturbing unaffected circuits.\u003c\/li\u003e \u003cli\u003ePlan for routine maintenance checks on connections and terminal torque to sustain reliable performance over the breaker’s service life.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eThe Schneider Electric NW25H2 2500A 3-Pole Air Circuit Breaker stands out as a purpose-built solution for robust, controllable protection in low-voltage power distribution. If you’re seeking dependable main-equipment protection with customizable trip coordination, this NW25H2 model delivers the reliability and flexibility your industrial or commercial facility demands.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default","offer_id":46390489186466,"sku":"NW25H2","price":20821.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/master_generic_382bbcae-f0f1-4800-8bc7-8ecf3a5cf89b.png?v=1765373788","url":"https:\/\/www.ampstate.com\/products\/schneider-electric-nw25h2-2500a-3-pole-air-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}