{"product_id":"schneider-electric-jdl36250aasa-250a-3p-600v-circuit-breaker","title":"Schneider Electric JDL36250AASA 250A 3P 600V Circuit Breaker, Shunt Trip, Auxiliary Switch | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the Schneider Electric \u003cstrong\u003eJDL36250AASA\u003c\/strong\u003e 250A, 3-pole, 600V circuit breaker — a purpose-built protection and control device designed for panelboards, load centers, and complex electrical distribution systems. With a focus on reliability, retrofit-friendly installation, and safer operation, this unit is ideal for installations where the part number must remain unchanged while upgrading protection and control capabilities.\u003c\/p\u003e \u003ch3\u003eWhy this breaker stands out\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHigh-ampacity protection:\u003c\/strong\u003e 250 A, 3 poles, 600 V rating deliver robust overcurrent protection for large feeders and distribution circuits, reducing the risk of nuisance trips and equipment damage.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRemote shutdown with shunt trip:\u003c\/strong\u003e The integrated shunt-trip feature enables quick, remote circuit disconnection for emergency response or maintenance safety, without requiring access to the breaker handle.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eImmediate control feedback:\u003c\/strong\u003e Built-in auxiliary switch provides real-time status signaling, simplifying control logic, fault diagnosis, and integration with building management or automation systems.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRetrofit-friendly design:\u003c\/strong\u003e Specifically engineered to upgrade existing installations without changing the part number, supporting smoother maintenance planning, stock consistency, and reduced downtime.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTrusted compatibility and support:\u003c\/strong\u003e From Schneider Electric, a widely deployed solution in panelboards and distribution networks, with AmpState readily available to confirm fit and readiness for your exact setup.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWho this is for\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eIndustrial facilities and commercial buildings upgrading electrical distribution where remote tripping and clear status feedback enhance safety and reliability.\u003c\/li\u003e \u003cli\u003eMaintenance teams planning retrofits or replacements that require preserving the exact part number for documentation, warranty, or inventory management.\u003c\/li\u003e \u003cli\u003eElectrical contractors seeking a robust, plug-in-ready solution for panelboards and load centers demanding both protective and control capabilities in a single device.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003ePractical use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\u003cstrongemergency shutdowns:\u003e In the event of equipment fault or safety concern, the shunt trip enables rapid, remote disconnection to protect personnel and assets.\u003c\/strongemergency\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMonitoring and signaling:\u003c\/strong\u003e The auxiliary contact communicates breaker status to control systems or building management interfaces, streamlining automation and diagnostics without extra wiring.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRetrofit projects:\u003c\/strong\u003e Upgrade feeders in existing installations while maintaining panelboard compatibility, boosting protection and control without modifying downstream infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eHow it compares to other configurations\u003c\/h3\u003e\n\u003cp\u003eThis device combines protection, remote tripping, and status signaling in a single unit, reducing wiring complexity and conserving panel real estate compared with separate protection and control components. Availability through AmpState simplifies stock checks and compatibility confirmation, helping you minimize installation delays and ensure a smooth procurement process.\u003c\/p\u003e \u003ch3\u003eInstallation tips and best practices\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eConfirm compatibility:\u003c\/strong\u003e Ensure the panelboard or distribution arrangement supports a 250 A, 3-pole, 600 V device with both shunt trip and auxiliary contact installed.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePlan remote wiring:\u003c\/strong\u003e Route the shunt-trip wiring to a clearly labeled control\/remote-disconnect point and verify control power requirements align with your system design.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInspect for space and bus compatibility:\u003c\/strong\u003e Verify available space and bus configuration in the panelboard to accommodate this 3-pole breaker without crowding adjacent components.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDocumentation and stocking:\u003c\/strong\u003e Keep the exact part number (JDL36250AASA) on hand for maintenance records, warranties, and future ordering to preserve system consistency.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eDesigned for performance, safety, and ease of maintenance, the Schneider Electric \u003cstrong\u003eJDL36250AASA\u003c\/strong\u003e delivers dependable overcurrent protection with enhanced control features for modern electrical distribution. Whether you’re upgrading a panelboard, expanding a load center, or planning a retrofit that must keep the same part number, this unit provides a cohesive, all-in-one solution that installers can trust.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AmpState","offers":[{"title":"Default Title","offer_id":46412987695266,"sku":"JDL36250AASA","price":11421.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/master_generic_83963f7f-600e-419f-90c6-e7677089642b.png?v=1765492973","url":"https:\/\/www.ampstate.com\/products\/schneider-electric-jdl36250aasa-250a-3p-600v-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}