{"product_id":"ite-siemens-slid4230g-100a-240v-fusible-bus-plug","title":"ITE\/Siemens SLID4230G - 100A, 240V, Fusible Bus Plug","description":"\u003cdiv\u003e\n\u003cp\u003eThe ITE\/Siemens SLID4230G Fusible Bus Plug is a purpose-built solution for reliable power distribution in demanding industrial and commercial environments. Rated at 100A and 240V, this fuse-protected bus plug integrates seamlessly with busway and panelboard systems, delivering controlled power flow where reliability matters most.\u003c\/p\u003e \u003cp\u003eWhy this bus plug stands out\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eExact 100A, 240V fusible protection\u003c\/strong\u003e—provides the appropriate overcurrent protection for critical circuits within busway and panelboard distributions, helping safeguard equipment and maintain uptime.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEngineered for busway and panelboard compatibility\u003c\/strong\u003e—designed to slot into Siemens\/ITE power distribution configurations, simplifying upgrades and retrofits without extensive redesigns.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eStrategic option for maintenance, repair, and upgrades\u003c\/strong\u003e—a hard-to-find, compatible bus plug that keeps existing systems in service and ready for modernization projects.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGenuine ITE\/Siemens component\u003c\/strong\u003e—authentic part lineage ensures fit, function, and long-term support within your distribution network.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eIdeal use cases for the SLID4230G\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eIndustrial plants seeking dependable, fuse-protected bus plug insertion to support essential process equipment and utilities.\u003c\/li\u003e \u003cli\u003eCommercial facilities undergoing capacity upgrades or system modernization where matching bus plugs are required for safe operation.\u003c\/li\u003e \u003cli\u003eRetrofit projects where compatible, hard-to-find busplugs are needed to extend the life of existing busway and panelboard infrastructure.\u003c\/li\u003e \u003cli\u003eMaintenance and repair scenarios that demand quick replacement parts to minimize downtime and keep power distribution running smoothly.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eHow the SLID4230G enhances operations\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eProtects downstream equipment\u003c\/strong\u003e by providing clear, fuse-based protection at the feed point for busway\/panelboard circuits.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupports seamless system upgrades\u003c\/strong\u003e—its compatibility with established busway and panelboard layouts helps facilities modernize without overhauling entire distributions.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eReduces downtime risks\u003c\/strong\u003e by offering a ready-to-install, genuine replacement where other parts may be scarce, ensuring quick restoration of service after faults or connector wear.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003ePractical guidance for getting the most from this part\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eUse in applications requiring a 100A, 240V fusible bus plug within compatible busway and panelboard systems.\u003c\/li\u003e \u003cli\u003ePlan replacements as part of routine maintenance, retrofits, or performance upgrades to minimize operational interruptions.\u003c\/li\u003e \u003cli\u003eConfirm system diagrams and wiring schematics point to a SLID4230G-compatible configuration before installation, and follow established safety procedures to de-energize equipment prior to handling.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWho should consider this product\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eMaintenance teams and facilities engineers managing aging or expanding power distribution networks.\u003c\/li\u003e \u003cli\u003eProject managers overseeing retrofit or upgrade initiatives that require authentic, compatible bus plugs.\u003c\/li\u003e \u003cli\u003eProcurement specialists sourcing dependable, long-lead replacements for Siemens\/ITE busway ecosystems.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWhy choose the SLID4230G over other options\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eAuthentic ITE\/Siemens part designed specifically for compatibility with Siemens\/ITE busway and panelboard systems, reducing integration risk.\u003c\/li\u003e \u003cli\u003eTargeted suitability for both industrial and commercial environments where reliable, fuse-protected distribution is essential.\u003c\/li\u003e \u003cli\u003eSpecialized availability for maintenance and retrofit projects, helping you secure a long-lasting, exact-fit solution when generic substitutes fall short.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eReady to secure dependable power distribution with a genuine SLID4230G fusible bus plug? Add this essential component to your cart and support your system’s longevity, safety, and uptime.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"ITE\/Siemens","offers":[{"title":"Default","offer_id":46392216977570,"sku":"SLID4230G","price":4197.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/master_generic_5d35ae65-0dbd-4282-9eda-1feb7d21cbbe.png?v=1765406180","url":"https:\/\/www.ampstate.com\/products\/ite-siemens-slid4230g-100a-240v-fusible-bus-plug","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}