{"product_id":"general-electrics-fcn36te050r2-50a-3-pole-bolt-on-circuit-breaker","title":"General Electrics FCN36TE050R2 - 50 A, 3-Pole Bolt-On Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Electrics FCN36TE050R2\u003c\/strong\u003e is a 50 A, 3-pole bolt-on molded case circuit breaker designed to deliver reliable branch circuit overcurrent and short-circuit protection in panelboards and load centers. Built for consistency and durability, this device keeps critical electrical systems safe in environments ranging from homes to light industrial settings.\u003c\/p\u003e \u003ch2\u003eWhy this breaker stands out\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSecure bolt-on mounting\u003c\/strong\u003e creates a rigid, vibration-resistant bus connection, minimizing movement and electrical stress in panels that experience regular vibration or motion.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e provides stable, repeatable protection by combining thermal overload sensing with magnetic short-circuit protection for fast, dependable response.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-compatible design\u003c\/strong\u003e is ready to integrate with matching load centers and panelboards, simplifying replacements and ensuring consistent performance across the system.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThree-pole configuration\u003c\/strong\u003e enables balanced protection for three-phase circuits, making it suitable for commercial and light industrial applications where three-phase services are common.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMolded case construction\u003c\/strong\u003e combines a compact footprint with robust enclosure protection, ideal for space-constrained panels without compromising safety.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electrics\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e FCN36TE050R2\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Thermal-magnetic molded case circuit breaker\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 50A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Bolt-on\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Branch circuit overcurrent and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential service panels and multi‑meter setups that require reliable 3‑pole protection for multi‑wire branch circuits.\u003c\/li\u003e \u003cli\u003eCommercial panelboards supporting lighting, HVAC, and small to mid-size equipment loads where a secure, vibration-resistant connection is valuable.\u003c\/li\u003e \u003cli\u003eLight industrial control panels that demand quick, precise tripping behavior to minimize system downtime after faults.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eHow it compares and practical considerations\u003c\/h3\u003e\n\u003cp\u003eCompared with other breakers in its class, the FCN36TE050R2 emphasizes vibration‑resistant mounting and a dependable thermal-magnetic trip response, helping you maintain consistent protection in environments with movement or vibration. Its bolt-on design streamlines installation in compatible OEM panels, reducing installation time and potential connection issues. When selecting a replacement or upgrade, ensure your panelboard is compatible with this 3‑pole, 50A unit to maintain proper coordination with downstream protective devices and meet electrical code requirements.\u003c\/p\u003e \u003ch3\u003ePro tips for installers and best practices\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eVerify panel compatibility before installation to ensure seamless integration with OEM load centers and panelboards.\u003c\/li\u003e \u003cli\u003eInspect bus connections for cleanliness and proper seating during bolt-on mounting to preserve a low‑impedance, secure connection.\u003c\/li\u003e \u003cli\u003eUse appropriate torque on mounting screws according to panel manufacturer specifications to prevent loosening from vibration.\u003c\/li\u003e \u003cli\u003eCoordinate with upstream protective devices to ensure selectivity and minimize nuisance tripping in multi‑breaker systems.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eFor dependable, project-ready branch circuit protection with steady 3‑phase performance, the FCN36TE050R2 from General Electrics offers a purpose-built solution that aligns with residential, commercial, and light industrial electrical needs. Available through AmpState, it’s a practical choice when you require a trusted, compatible bolt-on breaker that won’t compromise on protection or reliability.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349722124450,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/general_electric_breaker_and_panel_582f67fc-1643-428e-b43d-69f7b054be42.png?v=1764155060","url":"https:\/\/www.ampstate.com\/products\/general-electrics-fcn36te050r2-50a-3-pole-bolt-on-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}