{"product_id":"general-electric-sb363rgri-fusible-bus-plug","title":"General Electric | SB363RGRI | Fusible Bus Plug | 100A | 3-Pole | 600V","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the General Electric SB363RGRI Fusible Bus Plug — a purpose-built 100A, 3-Pole, 600V module designed for GE switchgear maintenance, retrofit, and replacement. Engineered to GE’s exacting standards, this fusible bus plug delivers precise fit, dependable protection, and a straightforward path to keep critical three-phase power running smoothly.\u003c\/p\u003e \u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 100 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 600 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Fusible bus plug\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e SB363RGRI\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Maintenance, retrofit, and replacement in GE switchgear\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy this fusible bus plug matters\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDirect GE compatibility:\u003c\/strong\u003e Designed to align with GE equipment, ensuring correct contact geometry and interface with existing bus assemblies.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMinimized downtime:\u003c\/strong\u003e Engineered for straightforward installation, helping service teams swap in a fuse-capable plug quickly during maintenance or retrofits.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIntegrated fusible protection:\u003c\/strong\u003e Provides built-in protection within the bus arrangement to help isolate faults and protect downstream feeders when used as part of a coordinated protection scheme.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThree-phase integrity:\u003c\/strong\u003e The 3-Pole design provides synchronized switching across all phases, essential for balanced loads and reliable motor starting.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e600V suitability:\u003c\/strong\u003e Ideal for typical 600V distribution systems found in industrial environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBest reference for compatibility:\u003c\/strong\u003e The part number SB363RGRI is the most reliable reference when confirming fit with your GE gear.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eBest-use scenarios\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eRoutine GE switchgear maintenance where a fusible bus plug is required to restore protection and continuity.\u003c\/li\u003e \u003cli\u003eRetrofits that convert a non-fusible arrangement to fusible protection within GE panels, improving fault isolation.\u003c\/li\u003e \u003cli\u003eSpare parts for service fleets, reducing downtime when field replacements are needed.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eCompatibility and verification\u003c\/strong\u003e\u003cbr\u003e\nNotes: Confirm fit and ratings before ordering. The part number is the best reference for compatibility with specific GE equipment models. When verifying, consult your equipment manual or GE data sheets to ensure the bus plug matches the bus width, stud arrangement, and enclosure height of your panel.\u003c\/p\u003e \u003ch3\u003eInstallation and safety considerations\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSafety first:\u003c\/strong\u003e De-energize and lock out the equipment before handling or replacement. Use appropriate PPE and follow site safety procedures.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePre-install inspection:\u003c\/strong\u003e Inspect for any signs of damage or corrosion on the plug or surrounding bus hardware prior to installation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eProper fitment:\u003c\/strong\u003e Verify that the bus plug aligns with the existing bus bars and mounting interface to ensure reliable electrical contact.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePost-install checks:\u003c\/strong\u003e After installation, perform a basic continuity check and confirm that all three phases engage properly when tested under controlled conditions.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWho benefits most\u003c\/h3\u003e\n\u003cp\u003eFacilities operating GE-branded switchgear in 600V three-phase networks will find the SB363RGRI essential for reliable maintenance, targeted retrofits, and planned replacements. It’s particularly suitable for industrial plants, manufacturing floors, data centers, and any environment where precise GE compatibility and dependable protection are required.\u003c\/p\u003e \u003ch3\u003eCare, storage, and ongoing readiness\u003c\/h3\u003e\n\u003cp\u003eKeep spare SB363RGRI units in a clean, dry environment, sealed from dust and moisture. Label spares with asset IDs and service dates to simplify future maintenance, and routinely verify stored parts against inventory for up-to-date compatibility with your GE equipment.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":46425737724066,"sku":"SB363RGRI","price":2637.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/master_generic_a085eff1-75dd-47ee-b131-4c8df8f0489b.png?v=1765492976","url":"https:\/\/www.ampstate.com\/products\/general-electric-sb363rgri-fusible-bus-plug","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}