{"product_id":"ge-thql1115gf-15a-120v-1-pole-plug-in-circuit-breaker","title":"GE THQL1115GF - 15 A, 120 V, 1-Pole Plug-In Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eGE THQL1115GF is a 15A, 120V, 1-pole plug-in molded case circuit breaker designed to protect branch circuits in panelboards and loadcenters. Its fast plug-in connection supports quick installations and simple replacements, helping minimize downtime during panel servicing. The built-in thermal-magnetic trip unit delivers stable, repeatable protection against overcurrent and short circuits, safeguarding wiring and connected equipment across residential, commercial, and light industrial environments.\u003c\/p\u003e \u003cp\u003eThis breaker is engineered to fit seamlessly with matching OEM load centers and panelboards, ensuring dependable operation and a clean, organized electrical panel. With its 1-pole configuration, it provides targeted protection for a single phase circuit—ideal for lighting, receptacle runs, or dedicated equipment circuits commonly found in homes and small workplaces.\u003c\/p\u003e \u003ch3\u003eWhy the GE THQL1115GF stands out\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eFast plug-in connection\u003c\/strong\u003e for quick installation and effortless replacements, reducing panel downtime.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e delivers precise protection that responds consistently to both gradual overloads and sudden faults.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePlug-in molded case design\u003c\/strong\u003e combines compact form with reliable, durable protection suited to modern panelboards.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e15A, 120V, 1-pole\u003c\/strong\u003e configuration covers standard residential lighting and general outlet circuits with dependable safety limits.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM compatibility\u003c\/strong\u003e ensures a secure fit within GE-compatible load centers and panelboards, promoting long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eResidential electrical panels protecting lighting circuits, kitchen outlets, and general receptacle runs.\u003c\/li\u003e \u003cli\u003eSmall offices or retail spaces where quick breaker replacement minimizes service interruptions.\u003c\/li\u003e \u003cli\u003eWorkshops and light industrial setups needing a reliable, code-aligned single-pole protection solution.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical snapshot\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eAmperage rating: \u003cstrong\u003e15A\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003eVoltage rating: \u003cstrong\u003e120V\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003eNumber of poles: \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003eMounting style: \u003cstrong\u003ePlug-in\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003eType: \u003cstrong\u003eThermal-magnetic molded case circuit breaker\u003c\/strong\u003e\n\u003c\/li\u003e \u003cli\u003ePart number: \u003cstrong\u003eTHQL1115GF\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eInstallation and safety notes\u003c\/h3\u003e\n\u003cp\u003eFor a secure, reliable replacement or upgrade, follow these practical guidelines:\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003ePower down the panel and verify there is no voltage before removing or installing breakers.\u003c\/li\u003e \u003cli\u003eConfirm panel compatibility with GE OEM load centers and panelboards to ensure a proper fit and optimal performance.\u003c\/li\u003e \u003cli\u003eSeat the breaker firmly into the panel’s bus stabs until it’s clearly seated and stable.\u003c\/li\u003e \u003cli\u003eUse appropriate tools and observe all local electrical codes during installation and servicing.\u003c\/li\u003e \u003cli\u003eIf the breaker trips, inspect connected loads and circuits before resetting to ensure safe operation.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWhether you’re upgrading an aging panel, stocking spare parts for service vans, or outfitting a new installation, the GE THQL1115GF provides precise, reliable protection for essential circuits. With its plug-in convenience, robust thermal-magnetic protection, and OEM-compatible design, it’s a practical, long-lasting choice for safeguarding residential, commercial, and light industrial electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349714260130,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/ge-thql1115gf-15-a-120-v-1-pole-plug-in-circuit-breaker-ampstate-458.webp?v=1788713853","url":"https:\/\/www.ampstate.com\/products\/ge-thql1115gf-15a-120v-1-pole-plug-in-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}