{"product_id":"ge-7700-cutler-hammer-9800-unitrol-breaker-mcc-bucket-200-a-600-v-48-height-3-p-ampstate","title":"GE 7700 - Cutler Hammer 9800 Unitrol - Breaker MCC Bucket - 200 A, 600 V, 48\" Height, 3 P | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eFor plants relying on GE 7700 motor control centers, the GE 7700 Breaker MCC Bucket from AmpState is a purpose-built, field-ready replacement that keeps critical equipment online with minimal downtime. This 200 A, 600 V, 3-Pole unit is crafted to fit the GE 7700 series and serves as a reliable retrofit or direct replacement within existing lineups, backed by AmpState’s commitment to quality and support.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Breaker MCC Bucket in the GE 9800 Unitrol family, designed to integrate seamlessly with GE 7700 motor control centers.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eElectrical rating\u003c\/strong\u003e: 200 A, 600 V, 3-Pole configuration—built to handle demanding industrial motor control loads with stability and clear trip signaling.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePhysical fit\u003c\/strong\u003e: 48\" bucket height to align with standard MCC rack dimensions and spacing, ensuring straightforward retrofits without extensive cabinet modification.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIntended use\u003c\/strong\u003e: Ideal for replacement or retrofit projects in facilities using GE 7700 Unitrol equipment, including plants with pumps, fans, compressors, and other heavy-duty motors.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWhy this specific MCC bucket stands out\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDirect replacement or retrofit\u003c\/strong\u003e: Optimized to slot into GE 7700 motor control centers, reducing engineering guesswork and installation time while preserving system coordination and protection schemes.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eProven compatibility with 9800 Unitrol\u003c\/strong\u003e: Part of the trusted Unitrol lineup, designed to maintain consistent breaker performance, trip characteristics, and control logic within your existing architecture.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eReliability for demanding environments\u003c\/strong\u003e: Engineered to support continuous industrial operation, minimizing maintenance cycles and helping you meet uptime targets.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAmpState support\u003c\/strong\u003e: AmpState provides high-quality MCC buckets and retrofit solutions with global delivery and dedicated technical support, helping you source, install, and validate replacements with confidence.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eUse cases and scenarios\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMaintenance and asset refurbishment in manufacturing lines that rely on GE 7700 MCCs, where downtime must be minimized and compatibility is non-negotiable.\u003c\/li\u003e \u003cli\u003eRetrofits of aging or obsolete buckets within GE 7700 systems to restore performance without redesigning entire control cabinets.\u003c\/li\u003e \u003cli\u003eNew installations in facilities adopting 9800 Unitrol breakers for standardized protection across multiple motor-driven loads.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWho this is ideal for\u003c\/p\u003e \u003cul\u003e \u003cli\u003eIndustrial facilities with GE 7700 motor control centers seeking a trusted, easily replaceable MCC bucket.\u003c\/li\u003e \u003cli\u003eMaintenance teams and facility engineers aiming to simplify spare parts planning and retrofit operations.\u003c\/li\u003e \u003cli\u003eOEMs and contractors performing controlled upgrades to ensure compatibility and consistent protection schemes.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003ePractical tips for safer, smoother installation\u003c\/p\u003e \u003cul\u003e \u003cli\u003eConfirm the 48\" bucket height matches your MCC rack spacing to avoid clearance issues during replacement.\u003c\/li\u003e \u003cli\u003eVerify that the 200 A, 600 V, 3-Pole configuration aligns with your existing bus connections and protection settings in the GE 7700 system.\u003c\/li\u003e \u003cli\u003eCoordinate with AmpState’s technical support for any retrofit guidance or field-adjustment considerations to ensure seamless integration.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eUpgrade your GE 7700 motor control center with the GE 7700 Breaker MCC Bucket—engineered for compatibility, backed by AmpState expertise, and designed to keep your industrial operations running smoothly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AmpState","offers":[{"title":"Default Title","offer_id":46343269744802,"sku":null,"price":18010.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/ge_7700_mcc_bucket_3ecb652a-71c5-4f35-8d82-4ab19ae901b4.jpg?v=1763940476","url":"https:\/\/www.ampstate.com\/products\/ge-7700-cutler-hammer-9800-unitrol-breaker-mcc-bucket-200-a-600-v-48-height-3-p-ampstate","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}