{"product_id":"ge-7098-cutler-hammer-9800-unitrol-breaker-mcc-bucket-50-a-480-v-18-height-3-p-ampstate","title":"GE 7098 - Cutler Hammer 9800 Unitrol - Breaker MCC Bucket - 50 A, 480 V, 18\" Height, 3 P | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eGE 7098 Breaker MCC Bucket\u003c\/strong\u003e from AmpState is a purpose-built, OEM-grade component designed for industrial motor control centers. Part of the \u003cem\u003eGE 9800 Unitrol\u003c\/em\u003e series, this 3‑pole breaker MCC bucket delivers reliable protection and control for critical plant equipment. With a 50 A, 480 V rating and an 18\" height, it’s crafted to fit seamlessly into GE 7098 MCC lineups as a direct replacement or retrofit option.\u003c\/p\u003e \u003ch3\u003eKey specifications at a glance\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBrand\/Series:\u003c\/strong\u003e GE, 9800 Unitrol\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Breaker MCC Bucket\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 50 A, 480 V, 3‑Pole\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBucket Height:\u003c\/strong\u003e 18 inches\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Fits GE 7098 motor control centers\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eThis MCC bucket is specifically engineered for \u003cstrong\u003eindustrial motor control applications\u003c\/strong\u003e where dependable protection and quick swapping matter. Its design ensures a snug fit within GE 7098 centers, enabling a straightforward \u003cem\u003edirect replacement\u003c\/em\u003e or seamless retrofit to upgrade an aging lineup without major cabinet modifications.\u003c\/p\u003e \u003ch3\u003eWhy this bucket stands out\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-Grade reliability:\u003c\/strong\u003e As part of the \u003cem\u003eUnitrol\u003c\/em\u003e family, it aligns with GE’s control platform for consistent performance and interoperability with existing components.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEfficient retrofit option:\u003c\/strong\u003e Use as a drop-in replacement or as part of a targeted upgrade to refresh a legacy MCC row, reducing downtime and maintenance complexity.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eClear electrical ratings for planning:\u003c\/strong\u003e 50 A at 480 V in a 3‑pole configuration covers a wide range of motor and line protection scenarios common in process, manufacturing, and facility systems.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMechanical compatibility:\u003c\/strong\u003e The 18\" bucket height is designed to integrate with standard GE 7098 footprints, simplifying installation and alignment with bus bars, meters, and control wiring.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use scenarios\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eIndustrial facilities with GE 7098 motor control centers that require an \u003cstrong\u003eefficient replacement\u003c\/strong\u003e for aging MCC buckets.\u003c\/li\u003e \u003cli\u003eRetrofits aimed at upgrading protection schemes for fans, pumps, conveyors, and other line-driven equipment operating at 480 V three-phase power.\u003c\/li\u003e \u003cli\u003eMaintenance budgets targeting minimized downtime during component swaps, thanks to a direct compatibility focus.\u003c\/li\u003e \u003cli\u003eNew-build projects that want to maintain a consistent control architecture by sticking with GE’s 9800 Unitrol platform.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003ePractical tips for installation and care\u003c\/h3\u003e\n\u003cp\u003eTo ensure a smooth swap or retrofitting process, verify the MCC center’s current configuration and confirm that a 50 A, 480 V, 3‑pole bucket matches the existing protection scheme. Handle the MCC bucket with standard electrical safety practices, and schedule installation during a planned maintenance window to minimize impact on production. After installation, perform a routine electrical test of the protected circuit and verify proper alignment with bus bars and wiring terminals.\u003c\/p\u003e \u003ch3\u003eAmpState value proposition\u003c\/h3\u003e\n\u003cp\u003eAmpState specializes in high-quality MCC buckets and retrofit solutions, backed by global delivery and technical support for industrial motor control applications. When you choose this GE 7098 Breaker MCC Bucket, you’re not only selecting a component—you’re aligning with a partner that understands the critical balance between \u003cstrong\u003ereliability\u003c\/strong\u003e, \u003cstrong\u003eease of replacement\u003c\/strong\u003e, and \u003cstrong\u003elong-term serviceability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AmpState","offers":[{"title":"Default Title","offer_id":46343973437602,"sku":null,"price":4210.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/ge_7098_mcc_bucket_02466284-b031-4aa6-99e8-6fb7402ff2fe.jpg?v=1763952739","url":"https:\/\/www.ampstate.com\/products\/ge-7098-cutler-hammer-9800-unitrol-breaker-mcc-bucket-50-a-480-v-18-height-3-p-ampstate","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}