{"product_id":"eaton-pdg23g0225tffj-250a-600v-3-pole-circuit-breaker","title":"Eaton PDG23G0225TFFJ - 250 A, 600 V, 3-Pole Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the Eaton PDG23G0225TFFJ, a 250 A, 600 V, 3-pole molded case circuit breaker engineered for dependable branch circuit protection in panelboards and load centers. Available from AmpState, this device blends compact design with precise Thermal–Magnetic protection to keep electrical systems running smoothly while preserving panel space.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhy it stands out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSpace-efficient design\u003c\/strong\u003e: The compact molded case form minimizes panel intrusion while delivering full protection for high-current circuits.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e: Combines temperature-based overload monitoring with instantaneous magnetic tripping, providing stable, repeatable protection across varying loads and temperatures.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-friendly compatibility\u003c\/strong\u003e: Specifically designed to drop into matching Eaton OEM loadcenters and panelboards, simplifying installation and future replacements.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile across sectors\u003c\/strong\u003e: Suitable for residential, commercial, and light industrial electrical distributions that require reliable 250 A protection at up to 600 V.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e PDG23G0225TFFJ\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Thermal-magnetic molded case circuit breaker\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 250 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Branch circuit overcurrent and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cp\u003eUse this 3-pole 250 A breaker to safeguard feeders and branch circuits within panelboards and load centers where robust protection is essential. It excels in:\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eNew commercial electrical distributions requiring reliable 250 A protection at 600 V\u003c\/li\u003e \u003cli\u003eRetrofits or replacements in compatible OEM panels, maintaining consistent protection characteristics\u003c\/li\u003e \u003cli\u003eLarge residential or light industrial installations needing consolidated, high-current fault protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eCompatibility and installation\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eConfirm the panel is designed for 3-pole, 250 A protection at up to 600 V and compatible with Eaton PDG series devices.\u003c\/li\u003e \u003cli\u003eInstall only within matching OEM loadcenters and panelboards to ensure proper fit and listed protection.\u003c\/li\u003e \u003cli\u003eFollow panel labeling for correct mounting orientation and bus connection to achieve proper trip performance.\u003c\/li\u003e \u003cli\u003eAdhere to local electrical codes and the manufacturer’s installation instructions for safe operation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy this matters\u003c\/h3\u003e\n\u003cp\u003eElectrical distribution hinges on fast, reliable fault clearing. The PDG23G0225TFFJ’s thermal-magnetic trip unit detects both gradual overloads and sudden short circuits, delivering prompt protection to conductors and downstream equipment. Its molded case construction stands up to field conditions while maintaining consistent trip characteristics, giving you confidence across a range of temperatures and load profiles.\u003c\/p\u003e \u003ch3\u003ePractical tips for best results\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003ePlan your panel layout to accommodate the 3-pole unit and maintain accessible servicing space.\u003c\/li\u003e \u003cli\u003eKeep accurate protection schematics and labeling for easy future maintenance or upgrades.\u003c\/li\u003e \u003cli\u003eMatch amperage and voltage ratings when replacing or upgrading to preserve the intended protection curve and performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349655507106,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/eaton-pdg23g0225tffj-250-a-600-v-3-pole-circuit-breaker-ampstate-590.webp?v=1788703372","url":"https:\/\/www.ampstate.com\/products\/eaton-pdg23g0225tffj-250a-600v-3-pole-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}