{"product_id":"eaton-edc2125l-125a-240v-2-pole-circuit-breaker","title":"Eaton EDC2125L - 125 A, 240 V, 2-Pole Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eEaton EDC2125L\u003c\/strong\u003e is a reliably protective solution for modern electrical panels. This 125 A, 240 V, 2-pole molded case circuit breaker provides essential branch circuit overcurrent and short-circuit protection in panelboards and loadcenters. With a compact molded case design and a thermal-magnetic trip unit, it delivers stable, repeatable protection across varied loads and environmental conditions, making it a trusted component for residential, commercial, and light industrial settings.\u003c\/p\u003e \u003ch3\u003eWhy this breaker stands out\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eCompact molded case design\u003c\/strong\u003e optimizes panel space, enabling cleaner wiring routes and easier future upgrades.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e provides precise, predictable interruption behavior—adapting to temperature changes and load fluctuations while minimizing nuisance trips.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003e125 A, 240 V, 2-pole configuration\u003c\/strong\u003e delivers robust protection for larger branch circuits commonly found in panelboards and loadcenters.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-compatible compatibility\u003c\/strong\u003e is designed to work with matching Eaton OEM loadcenters and panelboards, ensuring streamlined replacement and dependable coordination with upstream devices.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile application\u003c\/strong\u003e suitable for residential, commercial, and light industrial environments, where reliable fault protection and easy maintenance matter most.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhat problems does it solve?\u003c\/h3\u003e\n\u003cp\u003eWhether you’re upgrading an aging panel, replacing a failed breaker, or installing a new system, the Eaton EDC2125L provides \u003cstrong\u003ereliable overcurrent and short-circuit protection\u003c\/strong\u003e that helps prevent wiring damage, reduce fire risk, and minimize downtime. The thermal-magnetic design delivers consistent trip behavior across ambient temperatures and loads, so you don’t have to second-guess protection when circuits spike or heat up during peak use.\u003c\/p\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eReplacing a worn or tripped 2-pole breaker in residential loadcenters that require Eaton OEM compatibility.\u003c\/li\u003e \u003cli\u003eUpgrading panel capacity for harder-working circuits in small businesses or light industrial spaces.\u003c\/li\u003e \u003cli\u003eNew installations where dependable 2-pole protection at 125 A and 240 V is needed for large branch circuits.\u003c\/li\u003e \u003cli\u003ePanel modernization projects that benefit from space-saving, modular breaker design.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical snapshot\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\u003cstrongmanufacturer:\u003e Eaton\u003c\/strongmanufacturer:\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongpart number:\u003e EDC2125L\u003c\/strongpart\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongtype:\u003e Thermal-magnetic molded case circuit breaker\u003c\/strongtype:\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongampere rating:\u003e 125 A\u003c\/strongampere\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongvoltage rating:\u003e 240 V\u003c\/strongvoltage\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongpoles:\u003e 2\u003c\/strongpoles:\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongapplication:\u003e Branch circuit overcurrent and short-circuit protection\u003c\/strongapplication:\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eCompatibility and installation notes\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal performance, pair the Eaton EDC2125L with matching OEM loadcenters and panelboards. Verify that the panel labeling and upstream protection align with a 125 A, 240 V, 2-pole device. When replacing an existing breaker, confirm that the replacement amperage and pole configuration match the original for proper coordination and safe operation. If you’re expanding or upgrading, this breaker’s compact profile helps conserve space while maintaining robust protection for larger branch circuits.\u003c\/p\u003e \u003ch3\u003eWhy choose AmpState\u003c\/h3\u003e\n\u003cp\u003eAmpState offers trusted electrical components with clear compatibility guidance and reliable stock for quick turnarounds. The Eaton EDC2125L from AmpState helps property owners, electricians, and facility managers keep panels safe, compliant, and ready for everyday demand—without guesswork or unnecessary downtime.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349532496034,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/eaton-edc2125l-125-a-240-v-2-pole-circuit-breaker-ampstate-breakers-903.webp?v=1788679971","url":"https:\/\/www.ampstate.com\/products\/eaton-edc2125l-125a-240v-2-pole-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}