{"product_id":"eaton-dnpl220230-30a-240v-plug-in-circuit-breaker","title":"Eaton DNPL220230 - 30 A, 240 V Plug-In Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eMeet the Eaton DNPL220230 — a plug-in molded case circuit breaker designed to protect your electrical system with clarity and reliability. At 30A and 240V, this device delivers dependable branch-circuit overcurrent and short-circuit protection in panelboards and load centers, making it a practical upgrade or replacement choice for residential, commercial, and light industrial environments. Available through AmpState, it adopts a fast plug-in connection for quick, tool-free installation and swift service when circuits change.\u003c\/p\u003e \u003cp\u003eKey to its performance is the thermal-magnetic trip unit. The thermal element handles sustained overcurrent with precise, repeatable protection, while the magnetic element activates on high-energy faults for immediate response to short circuits. The result is predictable protection curves you can trust, reducing nuisance trips and safeguarding sensitive loads from power disturbances.\u003c\/p\u003e \u003ch3\u003eWhy this matters for your panel\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003ePlug-in convenience:\u003c\/b\u003e a secure, reliable connection that simplifies installation and minimizes downtime during upgrades or replacements.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eConsistent protection:\u003c\/b\u003e thermal-magnetic operation provides stable trip behavior across varying temperatures and loads.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eOEM-aligned compatibility:\u003c\/b\u003e designed to fit and function with matching Eaton OEM load centers and panelboards for seamless integration.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVersatile applications:\u003c\/b\u003e ideal for residential service panels, small-to-medium commercial panels, and light industrial subpanels that require robust branch-circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eSpecifications at a glance\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e Eaton\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003ePart Number:\u003c\/b\u003e DNPL220230\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eType:\u003c\/b\u003e Thermal-magnetic molded case circuit breaker\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eAmperage Rating:\u003c\/b\u003e 30A\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVoltage Rating:\u003c\/b\u003e 240V\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMounting Style:\u003c\/b\u003e Plug-in\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eApplication:\u003c\/b\u003e Branch circuit overcurrent and short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cp\u003eUse the Eaton DNPL220230 when upgrading or expanding panelboards and load centers in:\u003c\/p\u003e\n\u003cul\u003e \u003cli\u003eResidential service panels adding circuits or replacing aging breakers\u003c\/li\u003e \u003cli\u003eCommercial electrical rooms serving lighting, HVAC, or receptacle circuits\u003c\/li\u003e \u003cli\u003eLight industrial subpanels supporting shop equipment and machinery\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003ePractical tips for installation and operation\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eVerify you’re matching the DNPL220230 with the corresponding OEM load center or panelboard to ensure proper fit and electrical characteristics.\u003c\/li\u003e \u003cli\u003eBefore replacement, de-energize the panel and follow lockout\/tagout procedures. Handle the plug-in breaker with clean, dry hands to maintain optimal contact.\u003c\/li\u003e \u003cli\u003eWhen installing, ensure the plug-in connections are fully seated to prevent arcing and ensure consistent trip performance.\u003c\/li\u003e \u003cli\u003eUse the 30A, 240V rating for circuits that demand moderate to high current protection, such as multi-outlet branches or equipment feeds in light commercial settings.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eThe Eaton DNPL220230 is more than just a breaker—it’s a deliberate choice for reliable protection, straightforward installation, and long-term compatibility with Eaton’s panelboard ecosystem. Whether you’re upgrading an existing panel or equipping a new installation, this plug-in molded case circuit breaker delivers predictable performance when every milliamp of protection matters.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349530136738,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/eaton_breaker_and_panels_81836ae1-71f5-43cd-b594-bddce79b77b8.png?v=1764148928","url":"https:\/\/www.ampstate.com\/products\/eaton-dnpl220230-30a-240v-plug-in-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}