{"product_id":"eaton-cutler-hammer-fdpw368b-1200a-3-pole-vertical-bottom-feed-main-fusible-panel-mount-switch-fdpw-series","title":"Eaton \/ Cutler-Hammer FDPW368B – 1200A, 3-Pole Vertical Bottom Feed Main Fusible Panel-Mount Switch – FDPW Series","description":"\u003cdiv\u003e\n\u003cp\u003eThe Eaton \/ Cutler-Hammer FDPW368B is the robust main fusible panel-mount switch your switchgear relies on for dependable load isolation and overcurrent protection in demanding environments. Rated at 1200A in a 3-pole configuration, this device is engineered for panelboard and switchboard applications where safety, reliability, and fast fault clearance matter most. Its vertical bottom feed design supports streamlined wiring and compact enclosure layouts, making it a practical choice for large-draw industrial feeders.\u003c\/p\u003e \u003ch2\u003eCore strengths you’ll notice on day-to-day operation\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eHigh-current capability:\u003c\/strong\u003e 1200A continuous rating across a 3-pole configuration, enabling protection for substantial feeders and distribution circuits.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt for panel environments:\u003c\/strong\u003e Panel-mount construction designed to integrate cleanly into standard switchboards and panelboards, with a vertical bottom-feed orientation that simplifies wiring runs from the bottom of the enclosure.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIntegrated protection philosophy:\u003c\/strong\u003e Functions as a main fusible switch, delivering both mechanical disconnection and fuse-based overcurrent protection to minimize downstream fault propagation.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eIndustrial-duty reliability:\u003c\/strong\u003e Part of the FDPW Series, a family known for rugged performance in challenging industrial settings where uptime and predictable behavior are essential.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eIdeal use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eLarge-main feeders in switchboards or panelboards where a single, centralized disconnect and fuse protection is required before downstream circuits.\u003c\/li\u003e \u003cli\u003eIndustrial facilities with three-phase distribution needs—manufacturing floors, processing plants, and bulk-power enclosures—where reliable isolation is critical during maintenance or fault events.\u003c\/li\u003e \u003cli\u003eRetrofits or upgrades of existing FDPW-series installations, providing upgraded main protection without redesigning the panel layout.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eInstallation, compatibility, and practical considerations\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eThe vertical bottom-feed orientation is optimized for installations where wiring access comes from the bottom of the panel, helping simplify conduit routing and termination.\u003c\/li\u003e \u003cli\u003eDesigned for 3-phase electrical systems, delivering synchronized isolation across all phases to prevent phase-to-phase faults from propagating.\u003c\/li\u003e \u003cli\u003eAs a main fusible switch, ensure fuse elements and ratings align with your system’s fault currents and protection coordination requirements. This device is intended to be the primary protection point for large feeders within a panel or switchboard.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy choose the FDPW368B? Concrete advantages you won’t want to overlook\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eConsolidates disconnection capability with overcurrent protection in a single, panel-mount unit—reducing accessory components and potential points of failure.\u003c\/li\u003e \u003cli\u003eLong-term reliability for demanding industrial environments due to its heavy-duty construction and alignment with FDPW Series design principles.\u003c\/li\u003e \u003cli\u003eClear alignment with industrial power distribution needs: three-phase protection, high-current handling, and a mounting style that fits into established panel ecosystems.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003eWhether you’re protecting a heavy upstream feeder, planning a panel upgrade, or configuring a new switchboard installation, the FDPW368B delivers dedicated main protection with practical wiring accessibility and a proven track record in industrial applications. Tap into the strength of Eaton \/ Cutler-Hammer’s FDPW Series and ensure your distribution path remains isolated, protected, and ready for dependable operation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Eaton \/ Cutler-Hammer","offers":[{"title":"Default Title","offer_id":46361523060898,"sku":"FDPW368B","price":10.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/panel_mount_switches_p1_5cd4f6ab-efbb-40a0-b159-08b7ebb517dc.png?v=1764704057","url":"https:\/\/www.ampstate.com\/products\/eaton-cutler-hammer-fdpw368b-1200a-3-pole-vertical-bottom-feed-main-fusible-panel-mount-switch-fdpw-series","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}