{"product_id":"eaton-bab3060hs-60a-240v-3-pole-bolt-on-circuit-breaker","title":"Eaton BAB3060HS - 60 A, 240 V, 3-Pole Bolt-On Circuit Breaker | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eThe Eaton BAB3060HS stands as a dependable, ready-to-install solution for protecting branch circuits in panelboards and load centers. Delivering 60A at 240V with a rugged three-pole bolt-on design, this molded case circuit breaker is built to handle the demands of residential, commercial, and light industrial environments.\u003c\/p\u003e \u003ch3\u003eKey advantages that set the BAB3060HS apart\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eSecure bolt-on mounting\u003c\/strong\u003e for a rigid, vibration-resistant bus connection. This design minimizes loose connections and maintains consistent electrical contact in facilities where equipment experiences movement or vibration.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThermal-magnetic trip unit\u003c\/strong\u003e delivers stable, repeatable protection. The thermal element handles overloads predictably while the magnetic element provides fast, decisive response to short circuits, helping to minimize damage and downtime.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eThree-pole protection\u003c\/strong\u003e ensures balanced, coordinated shutdown across all phases in three-phase systems, reducing the risk of unmanaged fault currents and improving overall system safety.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOEM-compatible\u003c\/strong\u003e specifically engineered to integrate with matching Eaton panelboards and load centers, ensuring proper fit, electrical coordination, and ease of replacement without additional adaptors.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eVersatile application\u003c\/strong\u003e ideal for residential, commercial, and light industrial applications requiring reliable branch circuit overcurrent and short-circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhy this breaker matters for your panels\u003c\/h3\u003e\n\u003cp\u003eIf you’re upgrading or stocking spare parts for Eaton-compatible installations, the BAB3060HS provides a precise match for currently installed equipment. Its bolt-on design simplifies field replacement in panelboards and load centers, helping you maintain quick restoration of service with a secure, code-compliant connection. The 60A rating is well-suited for mid-size branch circuits, feeders, and equipment loads that demand robust protection.\u003c\/p\u003e \u003ch3\u003ePractical use cases\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003eMid-size commercial distribution panels where reliable three-phase protection keeps HVAC, lighting, and outlets safe from faults.\u003c\/li\u003e \u003cli\u003eResidential service panels with multi-wire branch circuits requiring clear overcurrent protection and straightforward maintenance.\u003c\/li\u003e \u003cli\u003eLight industrial panels powering small motors or conveyors where vibration resistance and dependable trip performance are critical.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eWhat you gain with the BAB3060HS\u003c\/h3\u003e\n\u003cul\u003e \u003cli\u003e\u003cstrongpredictable protection\u003e backed by a thermal-magnetic mechanism that reduces nuisance trips while preserving fast fault clearance.\u003c\/strongpredictable\u003e\u003c\/li\u003e \u003cli\u003e\u003cstronglong-term reliability\u003e thanks to a sturdy bolt-on mount that maintains a solid connection through years of service and minor disturbances.\u003c\/stronglong-term\u003e\u003c\/li\u003e \u003cli\u003e\u003cstrongeasy compatibility\u003e with Eaton’s family of panelboards and load centers, streamlining installation, maintenance, and future replacements.\u003c\/strongeasy\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch3\u003eTechnical snapshot\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003cbr\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e BAB3060HS\u003cbr\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Thermal-magnetic molded case circuit breaker\u003cbr\u003e\n\u003cstrong\u003eAmperage rating:\u003c\/strong\u003e 60A\u003cbr\u003e\n\u003cstrong\u003eVoltage rating:\u003c\/strong\u003e 240V\u003cbr\u003e\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003cstrong\u003eMounting style:\u003c\/strong\u003e Bolt-on\u003cbr\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Branch circuit overcurrent and short-circuit protection\u003c\/p\u003e \u003ch3\u003ePractical installation tips\u003c\/h3\u003e\n\u003cp\u003eEnsure the panelboard is de-energized before installation, torque mounting screws to the manufacturer’s specification, and verify that the breaker aligns properly with the bus bars. Confirm that the Eaton BAB3060HS is the correct matching unit for your specific load center or panelboard model to maintain proper electrical coordination and labeling.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Amp State","offers":[{"title":"Default Title","offer_id":46349493141666,"sku":null,"price":710.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/eaton_breaker_and_panels_a836b0d1-ea2d-4f75-928c-f07e61d76ff3.png?v=1764148139","url":"https:\/\/www.ampstate.com\/products\/eaton-bab3060hs-60a-240v-3-pole-bolt-on-circuit-breaker","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}