{"product_id":"canadian-controller-mcc-bucket-breaker-mcc-bucket-400-a-240-v-24-height-3-p-ampstate","title":"Canadian Controller - MCC Bucket - Breaker MCC Bucket - 400 A, 240 V, 24\" Height, 3 P | AmpState","description":"\u003cdiv\u003e\n\u003cp\u003eThe Canadian Controller MCC Bucket from AmpState is purpose-built for industrial motor control centers that demand a precise 400 A, 240 V, 3-Pole configuration. Designed as a direct replacement or retrofit, this Breaker MCC Bucket slides into Canadian Controller MCC lineups with ease, helping you modernize or expand your plant’s motor control infrastructure without disruptive system overhauls.\u003c\/p\u003e \u003ch2\u003eKey specifications at a glance\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eBucket configuration:\u003c\/strong\u003e Breaker MCC Bucket (3-Pole)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eElectrical rating:\u003c\/strong\u003e 400 A, 240 V\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBucket height:\u003c\/strong\u003e 24\"\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBrand \/ series:\u003c\/strong\u003e Canadian Controller\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Direct replacement or retrofit in MCC lineups for industrial motor control centers\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eWhy this MCC bucket matters\u003c\/h2\u003e\n\u003cp\u003eIn demanding industrial environments, you need a bucket that not only fits mechanically but also aligns with your electrical expectations. This Canadian Controller MCC Bucket delivers a reliable 3-Pole breaker solution capable of handling substantial load currents while maintaining a compact 24\" footprint suitable for standard MCC frames. Its 240 V design is ideal for facilities running mixed-voltage motor drives and feeders, enabling consistent performance across critical motor circuits.\u003c\/p\u003e \u003ch2\u003eIdeal use cases\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003eRetrofit aging MCCs to restore reliability and compatibility with newer motor controls\u003c\/li\u003e \u003cli\u003eExpand capacity in existing motor control centers without migrating to a new enclosure family\u003c\/li\u003e \u003cli\u003eInstall as a direct replacement in Canadian Controller MCC lineups for streamlined maintenance\u003c\/li\u003e \u003cli\u003eUpgrade plant infrastructure where 400 A, 240 V, 3-Pole control is required for heavy-duty motors\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eWhat sets it apart\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDirect replacement fit:\u003c\/strong\u003e Engineered to align with Canadian Controller MCC bucket footprints, reducing field rework and downtime.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDedicated retrofit option:\u003c\/strong\u003e A practical path to modernize existing MCCs without wholesale panel replacement.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRobust, field-ready design:\u003c\/strong\u003e Built to withstand the rigors of industrial environments while delivering dependable switching for motor loads.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eGlobal support:\u003c\/strong\u003e AmpState backs the product with worldwide delivery and technical assistance to keep projects on schedule.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eInstallation considerations and practical tips\u003c\/h2\u003e\n\u003cp\u003eBefore installation, verify that your panel chassis and bus arrangement match the 24\" bucket height and the 3-Pole breaker configuration. Confirm mounting ferrous compatibility and ensure proper alignment with adjacent MCC components to maintain safe isolation and accessible wiring routes. Follow standard lockout\/tagout procedures and consult your facility’s electrical specifications to integrate seamlessly with existing control circuitry and protection schemes.\u003c\/p\u003e \u003ch2\u003eWho this is for\u003c\/h2\u003e\n\u003cp\u003eFacility engineers, maintenance managers, and commissioning teams responsible for motor-driven processes in manufacturing, processing, and heavy industry will benefit from this solution. It’s particularly suited for plants running Canadian Controller MCC setups that require robust 400 A, 240 V, 3-Pole breakers and a straightforward retrofit or replacement path to minimize downtime.\u003c\/p\u003e \u003ch2\u003eDelivery and support\u003c\/h2\u003e\n\u003cp\u003eAmpState provides the Canadian Controller MCC Bucket as part of a comprehensive retrofit and replacement ecosystem. Expect reliable global delivery and access to technical support to help you plan, install, and validate your motor control center upgrades.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"AmpState","offers":[{"title":"Default Title","offer_id":46342765183138,"sku":null,"price":9510.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0666\/8094\/6850\/files\/mcc_bucket_generic_4db032c7-3c24-4f3b-afcd-042c99d8030b.png?v=1763922013","url":"https:\/\/www.ampstate.com\/products\/canadian-controller-mcc-bucket-breaker-mcc-bucket-400-a-240-v-24-height-3-p-ampstate","provider":"Ampstate Electric Corporation","version":"1.0","type":"link"}